Complete Combined Cycle 2 x GE LM6000PD Sprint Power Plant

Technical Information

1. Gas Turbine-1
Tag Information :
Brand Mark : GENERAL ELECTRİC
Model No: 7LM6000-PD-NGDG11
Rating: 46,500 KW
Speed: 10,400 RPM
Site Conditions: ISO
Operation Information
Operation Hours : 18,047 Hours (2011 to Dec 2017 ).
Operation Condition : The turbine runs mostly at base load that’s why the machine condition is very well. All maintenance is carried out in line with OEM from start up and all maintenance reports are available. COD is 2011
2. Gas Turbine-1 Gearbox
Mfgr: Lufkin Gears
Address: Lufkin Industries Inc. Lufkin, Texas
Model No: NFVQ2419D
Ratio: 1.209/1
Input Rpm: 3627 rpm
Output Rpm: 3000 rpm
Application Power: 70,000 HP
Production Year : 2009
3. Gas Turbine-1 Generator
Mfgr: MEIDEN.
Type: Frame :800LL07 EK-AFT
Machine No.: 1C6976RJ1
Rated Power : 64,500 kVA
Rated Voltage: 11,500 V
Rated Current: 3238 A
P.F.: 0,802
Frequency: 50 Hz
Speed: 3000 rpm
4. Gas Turbine-1 Start Motor
Motor No: M3GP 315SMC2B35
Production Year: 2009
Rated Power: 150 kw
Rated Speed ( RPM ): 29882
5. Gas Turbine-1 Transformer
Brand Mark: AREVA
Type: Power Transformer
Rated Power: 55/70 MVA
Rated Frequency: 50 Hz
Phase: 3
Applicable standards: TS-267 IEC60076
Rated Voltage: 34,5 kV / 11,5 KV
Rated Current: HV (1233 A ), LV ( 3514 A )
Insulation level: 170 kV / 70 kV
Vector group (connection symbol): YN d 5
Impedance voltage: 10.42%
Short Circuit Time: 3 seconds
Insulation Class: A
OFF LOAD TAP CHANGER
Type: ASP 30kV
Level Number: 5
6. Gas Turbine-2
Tag Information :
Brand Mark : GENERAL ELECTRİC
Model No: 7LM6000-PD-NGDG11
Rating: 46,500 KW
Speed: 10,400 RPM
Site Conditions: ISO
Operation Information :
Operation Hours : 16,940 Hours (2011 to Dec 2017)
Operation Condition : The turbine runs mostly at base load that’s why the machine condition is very well. The unit’s all maintenance is carried out by OEM annually from the beginning and all maintenance reports are available. COD is 2011.
7. Gas Turbine-2 Gearbox
Mfgr: Lufkin Gears
Address: Lufkin Industries Inc. Lufkin, Texas
Model No: NFVQ2419D
Ratio: 1.209/1
Input Rpm: 3627 rpm
Outpuy Rpm: 3000 rpm
Application Power: 70,000 HP
Product Year : 2009
8. Gas Turbine-2 Generator
Mfgr: MEIDEN.
Type: Frame :800LL07 EK-AFT
Machine No.: 1C6975RJ1
Rated Power : 64,500 kVA
Rated Voltage: 11,500 V
Rated Current: 3,238 A
P.F.: 0.80
Frequency: 50 Hz
Speed: 3000 rpm
9. Gas Turbine-2 Start Motor
Motor No: M3GP 315SMC2B35
Production Year: 2009
Rated Power: 150 kw
Rated Speed ( RPM ): 29882
10. Gas Turbine-2 Transformer
Brand Mark: AREVA
Type: Power Transformer
Rated Power: 55/70 MVA
Rated Frequency: 50 Hz
Phase: 3
Applicable standards: TS-267 IEC60076
Rated Voltage: 34.5 kV / 11.5 KV

Rated Current: HV (1233,1 A ), LV ( 3514,3 A )
Insulation level: 170 kV / 70 kV
Vector group (connection symbol): YN d 5
Impedance voltage: 10.42%
Short Circuit Time: 3 seconds
Insulation Class: A
OFF LOAD TAP CHANGER
Type: ASP 30kV
Level Number: 5
11. Steam Turbine
Tag Information
Brand: SIEMENS
Model : SST-400 C3L/V80.7AA
Rated Power: 27,960 kW
Speed: 4,200 rpm
Main Steam Press.: 53.1 Bar
Main Steam Temp.: 420 ˚C
Exhaust Steam Press.: 0.071 Bar
Operation Hours : 14,786 Hours (2011 – Dec 2017)
12.Steam Turbine Generator
Mfgr: ABB
Power : 35,400 kVA
Voltage: 11,500 V
Amper: 1777 A
Power Factor: 0,8 PF
Frequency: 50 Hz
Speed: 1500 rpm
Phases: 3 Phases
Type: AMS 1120 LG
Standart: IEC60034-1
Year : 2011
13. Steam Turbine Gearbox
Gear Box
Mfgr : RENK
Ratio : 2.804 : 1
5
Input Speed : 4207 rpm
Output Speed : 1500 rpm
Rated Power : 29,000 KW
Type: TLE-800
13.Steam Turbine Transformer
Type: YT 40000/36
Rated Power: 32,000/40,000 KVA
Rated Frequency: 50 Hz
Phase: 2
Applicable standards: TS-267 IEC 60076
Rated Voltage: 34.5 kV / 11.5 KV
Rated Current: HV (669.4 A ), LV (2008.1 A )
Insulation level: 170 kV / 70 kV
Vector group (connection symbol): YN d 5
Impedance voltage : 9.78 %
Short Circuit Time: 3 seconds
Insulation Class: A